Setting X Direction (Feed Direction) Divided Cutting
The data size in the feed direction will be cut divided at the positions corresponding to [Division Length + Cross Cut Length]. 
Setting the cross cut length cuts at the [Cut Length] position overlapping by the amount of the setting.
- Press the [FUNCTION] key in local mode.
 
- Use 
 to select [SET UP], then press the [ENTER/HOLD] key. 
- Use 
 to select [DIVISIONcut], then press the [ENTER/HOLD] key. 
- Use 
 to select [X], then press the [ENTER/HOLD] key. 
- Use 
 to select [DIV.LENG], then press the [ENTER/HOLD] key. 
- Setting: 50 to 500 cm (in 50 cm increments)
 
- Use 
 to select the [CROSS CUT] setting, then press the [ENTER/HOLD] key. 
- Setting: 0 to 50mm (in 1mm increments)
 
- The sheet is cut with overlaps corresponding to the amount of the setting.
 
- Press the [END] key several times to exit.
 

- The settings are retained even when the power is turned off.
 - The data from the host computer can be ignored during divided cutting.
 - Divided cutting is not possible in the following cases: 
- If the volume of cutting data exceeds the size of the receive buffer
- If the cutting data contains an origin update command
- If two-point line correction is set
- If register mark detection is used
- If the available cutting area is 1 cm or less
- If test data has been cut within the machine