- Please check the following contents.
1. Cautions for installation environment
Prepare a place that satisfies the following conditions.
(1) Make sure the place is within the specifications.
Operation environment: Temperature from 5°C to 35°C, humidity from 35% to 75% (Rh), non-condensing
Accuracy guaranteed environment: Temperature from 16°C to 32°C, humidity from 45% to 65% (Rh), non-condensing
(2) Not exposed to direct wind from an air conditioner and the like
(3) Not exposed to direct sunlight
(4) Horizontal
(5) No oscillation nor vibration
(6) Free from open fire
(7) Required installation space is secured
(8) Less dust [equivalent to general offices: airborne dust level 0.15mg/m3 or less]
2. Main unit dimensions and required installation area
The dimensions and the required installation area of the APC-130 main unit is as follows.
Secure a space for the main unit size and for works such as media replacement.
The main unit needs a 1,000mm or more space back and front of it and a 500mm or more space left and right of it.
* Other than for the APC-130 main unit, an extra space is necessary for the PC for outputting.
External dimensions
* The 1,110mm depth is the length when open the sheet basket to its fullest extent.
Required installation space